6. Rinse all equipment within 20 to 25 minutes after cleaning compound application. Using the same prerinse pattern as with the prerinse and deter¬gent application, spray 50 to 55°C water on one side of each piece of pro¬cessing equipment at a time.
7. Thoroughly inspect all equipment surfaces and touch up as necessary.
8. Apply an organic sanitizer to all clean equipment with a centralized or portable sanitizing unit.
9. Remove, clean, and replace drain covers.
10. Apply white edible oil only to surfaces subject to rust or corrosion.
11. Avoid contamination during mainte-nance as described previously.
Fresh Product Processing Areas
FREQUENCY Daily.
PROCEDURE
1. Dismantle all equipment, and place the parts on a table or rack. Discon¬nect all stuffing pipes.
2. Remove large debris from equipment and floor and deposit it in a receptacle.
3. Cover mixer and packaging equip¬ment with plastic.
4. Briefly prerinse all soiled surfaces with 50 to 55°C water to remove heavy debris and to soak exposed surfaces. Guide hoses to force all debris toward the closest floor drain.
5. Apply an alkaline cleaner through centralized or portable high-pressure, low-volume cleaning equipment, using 50 to 55°C water. Foam, gel, or slurry may be incorporated to intro¬duce the cleaning compound. Clean¬ing compound application must cover the entire area equipment, floors, walls, and doors.
6. Rinse the area and equipment within 20 to 25 minutes after cleaning com¬pound application.
7. inspect the area and all equipment. Touch up as needed.
8. Remove, clean, and replace drain covers.
9. Sanitize all clean equipment with an organic sanitizer using a centralized or portable sanitizing unit.
10. Apply white edible oil only to surfaces subject to rust or corrosion.
11. Avoid contamination during mainte-nance as described previously.