TerminalType Description FunctionDO1Output SignalMultifunctionaloutput dịch - TerminalType Description FunctionDO1Output SignalMultifunctionaloutput Việt làm thế nào để nói

TerminalType Description FunctionDO

Termin
al
Type Description Function
DO1
Output Signal
Multifunctional
output terminal 1
When the token function is true, the value
between this terminal and CM is 0V; when the
function is false, the value is 24V.
The functions of output
terminals shall be defined
per manufacturer’s value.
Their initial state may be
changed through changing
function codes.
DO2
Note 1 Multifunctional
TA output terminal 2
TB
TC Relay contact
TC is a common point, TB-TC are normally
closed contacts, TA-TC are normally open
contacts. The contact capacity is 10A/125VAC,
5A/250VAC, 5A/30VDC. (See note 3)
AO1
Analog output
Running frequency It is connected with frequency meter, speedometer or ammeter externally,
AO2 and its minus pole is connected with GND. See F423~F426 for details.
Note 1 Current display
10V Analog power
supply
Self contained
power supply
Internal 10V self-contained power supply of the inverter provides power to
the inverter. When used externally, it can only be used as the power supply
for voltage control signal, with current restricted below 20mA.
AI1
Input Signal Voltage / Current
analog input
When analog speed control is selected, the voltage or current signal is input
through this terminal. The range of voltage input is 0~10V and the current
input is 0~20mA, the input resistor is 500Ohm, and grounding: GND. If the
input is 4~20mA, it can be realised by setting F406 to 2. The voltage or
current signal can be chosen by coding switch. See Table 8-2 and Table
8- for details, the default setting of AI1 is 0~10V, and the default setting of
AI2 is 0-20mA.
AI2
GND
Self-contained
Power
supply Ground
Ground terminal of external control signal (voltage control signal or current
source control signal) is also the ground of 10V power supply of this
inverter.
24V Power
supply
Control power
supply
Power: 24±1.5V, grounding is CM; current is restricted below 50mA for
external use.
DI1
Digital input
control
terminal
Jogging terminal
When this terminal is valid, the
inverter will have jogging running.
The jogging function of this terminal
is valid under both at stopped and
running status.
The functions of input terminals shall
be defined per manufacturer’s value.
Other functions can also be defined
by changing function codes.
DI2 External
Coast Stop
When this terminal is valid, “ESP”
malfunction signal will be displayed.
DI3 “FWD” Terminal When this terminal is valid, inverter
will run forward.
DI4 “REV” Terminal When this terminal is valid, inverter
will run reverse.
DI5 Reset terminal Make this terminal valid under fault
status to reset the inverter.
DI6
Note 1 Free stop Make this terminal valid during running can realize free stop.
DI7
Note 1 Run Terminal
When this terminal is in the valid
state, inverter will run by the
acceleration time.
DI8
Note 1 Stop terminal
Make this terminal valid during
running can realize stop by the
deceleration time.
GND
Note 2
RS485
communication
terminals
Grounding of
differential signal Ground of differential signal
5V
Note 2
Power of
differential signal Power of differential signal
A+
Note 2
Positive polarity of
differential signal Standard: TIA/EIA-485(RS-485)
Communication protocol: Modbus
B- Communication rate: 1200/2400/4800/9600/19200/38400/57600bps
Note 2
Negative polarity of
Differential signal
Note 1: This terminal is not included in 22kW and below 22Kw inverters.
Note 2: For 30kW and above 30kW inverters, GND, 5V, A+, and B- are 4-pole terminal block. For below 30kW, there are no GND and 5V
terminals.
Note 3: The contact capacity for 30kW and above 30kW inverters is 10A/125VAC, NO/NC 3A, 250VAC/30VDC.
0/5000
Từ: -
Sang: -
Kết quả (Việt) 1: [Sao chép]
Sao chép!
TerminalType Description FunctionDO1Output SignalMultifunctionaloutput terminal 1When the token function is true, the valuebetween this terminal and CM is 0V; when thefunction is false, the value is 24V.The functions of outputterminals shall be definedper manufacturer’s value.Their initial state may bechanged through changingfunction codes.DO2Note 1 MultifunctionalTA output terminal 2TBTC Relay contactTC is a common point, TB-TC are normallyclosed contacts, TA-TC are normally opencontacts. The contact capacity is 10A/125VAC,5A/250VAC, 5A/30VDC. (See note 3)AO1Analog outputRunning frequency It is connected with frequency meter, speedometer or ammeter externally,AO2 and its minus pole is connected with GND. See F423~F426 for details.Note 1 Current display10V Analog powersupplySelf containedpower supplyInternal 10V self-contained power supply of the inverter provides power tothe inverter. When used externally, it can only be used as the power supplyfor voltage control signal, with current restricted below 20mA.AI1Input Signal Voltage / Currentanalog inputWhen analog speed control is selected, the voltage or current signal is inputthrough this terminal. The range of voltage input is 0~10V and the currentinput is 0~20mA, the input resistor is 500Ohm, and grounding: GND. If theinput is 4~20mA, it can be realised by setting F406 to 2. The voltage orcurrent signal can be chosen by coding switch. See Table 8-2 and Table8- for details, the default setting of AI1 is 0~10V, and the default setting ofAI2 is 0-20mA.AI2GNDSelf-containedPowersupply GroundGround terminal of external control signal (voltage control signal or currentsource control signal) is also the ground of 10V power supply of thisinverter.24V PowersupplyControl powersupplyPower: 24±1.5V, grounding is CM; current is restricted below 50mA forexternal use.DI1Digital inputcontrolterminalJogging terminalWhen this terminal is valid, theinverter will have jogging running.The jogging function of this terminalis valid under both at stopped andrunning status.The functions of input terminals shallbe defined per manufacturer’s value.Other functions can also be definedby changing function codes.DI2 ExternalCoast StopWhen this terminal is valid, “ESP”malfunction signal will be displayed.DI3 “FWD” Terminal When this terminal is valid, inverterwill run forward.DI4 “REV” Terminal When this terminal is valid, inverterwill run reverse.DI5 Reset terminal Make this terminal valid under faultstatus to reset the inverter.DI6Note 1 Free stop Make this terminal valid during running can realize free stop.DI7Note 1 Run TerminalWhen this terminal is in the validstate, inverter will run by theacceleration time.DI8Note 1 Stop terminalMake this terminal valid duringrunning can realize stop by thedeceleration time.GNDNote 2RS485communicationterminalsGrounding ofdifferential signal Ground of differential signal5VNote 2Power ofdifferential signal Power of differential signalA+Note 2Positive polarity ofdifferential signal Standard: TIA/EIA-485(RS-485)Communication protocol: ModbusB- Communication rate: 1200/2400/4800/9600/19200/38400/57600bpsNote 2Negative polarity ofDifferential signalNote 1: This terminal is not included in 22kW and below 22Kw inverters.Note 2: For 30kW and above 30kW inverters, GND, 5V, A+, and B- are 4-pole terminal block. For below 30kW, there are no GND and 5Vterminals.Note 3: The contact capacity for 30kW and above 30kW inverters is 10A/125VAC, NO/NC 3A, 250VAC/30VDC.
đang được dịch, vui lòng đợi..
Kết quả (Việt) 2:[Sao chép]
Sao chép!
Termin
al
Loại Mô tả Chức năng
DO1
Tín hiệu đầu ra
đa chức năng
đầu ra thiết bị đầu cuối 1
Khi chức năng mã thông báo là đúng, giá trị
giữa các thiết bị đầu cuối này và CM là 0V; khi
chức năng là sai, giá trị là 24V.
Các chức năng của đầu ra
thiết bị đầu cuối được xác định
cho mỗi giá trị của nhà sản xuất.
trạng thái ban đầu của họ có thể được
thay đổi thông qua việc thay đổi
mã số chức năng.
DO2
Note 1 đa chức năng
hỗ trợ kỹ thuật thiết bị đầu cuối đầu ra 2
TB
TC Tiếp xúc
TC là một phổ biến điểm, TB-TC thường
liên lạc kín, TA-TC là thường mở
danh bạ. Khả năng liên lạc là 10A / 125VAC,
5A / 250VAC, 5A / 30VDC. (Xem chú thích 3)
AO1
đầu ra Analog
Chạy tần số được kết nối với đồng hồ tần số, đồng hồ tốc độ hay ampe kế bên ngoài,
AO2 và trừ của nó cực được kết nối với GND. Xem F423 ~ F426 để biết chi tiết.
Lưu ý 1 Màn hình hiện
10V Analog điện
cung cấp
tự chứa
cung cấp điện
nội bộ 10V cung cấp điện độc lập của các biến tần cung cấp nguồn cho
các biến tần. Khi được sử dụng bên ngoài, nó chỉ có thể được sử dụng như là nguồn cung cấp năng lượng
cho tín hiệu điều khiển điện áp, với hiện tại bị hạn chế dưới 20mA.
AI1
Tín hiệu đầu vào điện áp / hiện tại
đầu vào tương tự
khi kiểm soát tốc độ tương tự được chọn, các điện áp hoặc tín hiệu hiện nay là đầu vào
thông qua thiết bị đầu cuối này. Phạm vi của các điện áp đầu vào là 0 ~ 10V và dòng điện
đầu vào là 0 ~ 20mA, điện trở đầu vào là 500Ohm, và nền tảng: GND. Nếu
đầu vào là 4 ~ 20mA, nó có thể được thực hiện bằng cách thiết lập F406 đến 2. Các điện áp hoặc
tín hiệu hiện tại có thể được lựa chọn bằng cách mã hóa chuyển đổi. Xem Bảng 8-2 và Bảng
8- để biết chi tiết, các thiết lập mặc định của AI1 0 ~ 10V, và các thiết lập mặc định của
AI2 là 0-20mA.
AI2
GND
Khép kín
điện
cung trệt
mặt đất thiết bị đầu cuối của tín hiệu điều khiển bên ngoài (điều khiển điện áp tín hiệu hoặc hiện
tín hiệu điều khiển nguồn) cũng là mặt đất của nguồn điện 10V này
biến tần.
24V điện
cung cấp
điều khiển điện
cung cấp
điện: 24 ± 1.5V, nền tảng là CM; hiện tại bị hạn chế dưới 50mA cho
sử dụng ngoài da.
DI1
đầu vào kỹ thuật số
kiểm soát
thiết bị đầu cuối
Chạy bộ thiết bị đầu cuối
Khi thiết bị đầu cuối này là hợp lệ,
biến tần sẽ phải chạy bộ chạy.
Các chức năng chạy bộ của thiết bị đầu cuối này
là hợp lệ theo cả dừng lại và
tình trạng hoạt động.
Các chức năng của thiết bị đầu cuối đầu vào sẽ
được xác định theo giá trị của nhà sản xuất.
Các chức năng khác cũng có thể được xác định
bằng cách thay đổi mã số chức năng.
DI2 ngoài
Coast Dừng
Khi thiết bị đầu cuối này là hợp lệ, "ESP"
tín hiệu sự cố sẽ được hiển thị.
DI3 "FWD" terminal Khi thiết bị đầu cuối này là hợp lệ, biến tần
sẽ chạy về phía trước.
DI4 "REV" terminal Khi thiết bị đầu cuối này là hợp lệ, biến tần
sẽ chạy ngược.
DI5 đặt lại thiết bị đầu cuối Hãy thiết bị đầu cuối này có hiệu lực theo lỗi
tình trạng để reset.
DI6
Note 1 miễn phí ngăn chặn Hãy thiết bị đầu cuối này có hiệu lực trong thời gian chạy có thể nhận ra dừng tự do.
DI7
Note 1 Run ga
Khi thiết bị đầu cuối này nằm ở giá trị
nhà nước, biến tần sẽ chạy theo
thời gian tăng tốc.
DI8
Note 1 dừng thiết bị đầu cuối
Hãy thiết bị đầu cuối này có giá trị trong
chạy có thể nhận ra điểm dừng của
thời gian giảm tốc.
GND
Note 2
RS485
giao tiếp
thiết bị đầu cuối
nối đất của
khác biệt tín hiệu mặt đất của tín hiệu khác biệt
5V
Note 2
Sức mạnh của
khác biệt điện tín hiệu của tín hiệu khác biệt
A +
Lưu ý 2
cực dương của
tiêu chuẩn tín hiệu khác biệt: TIA / EIA-485 (RS-485)
Giao thức truyền thông: Modbus
B- Truyền suất: 1200/2400/4800 / 9600/19200/38400 / 57600bps
Note 2
cực âm của
Differential tín hiệu
Ghi chú 1:. thiết bị đầu cuối này không được bao gồm trong 22kW và dưới biến tần 22kW
Lưu ý 2: Đối với 30kW và trên biến tần 30kW, GND, 5V, A +, và B- là 4 cực terminal block. Đối với bên dưới 30kW, không có GND và 5V
thiết bị đầu cuối.
Lưu ý 3: Khả năng liên lạc cho 30kW và trên biến tần 30kW là 10A / 125VAC, NO / NC 3A, 250VAC / 30VDC.
đang được dịch, vui lòng đợi..
 
Các ngôn ngữ khác
Hỗ trợ công cụ dịch thuật: Albania, Amharic, Anh, Armenia, Azerbaijan, Ba Lan, Ba Tư, Bantu, Basque, Belarus, Bengal, Bosnia, Bulgaria, Bồ Đào Nha, Catalan, Cebuano, Chichewa, Corsi, Creole (Haiti), Croatia, Do Thái, Estonia, Filipino, Frisia, Gael Scotland, Galicia, George, Gujarat, Hausa, Hawaii, Hindi, Hmong, Hungary, Hy Lạp, Hà Lan, Hà Lan (Nam Phi), Hàn, Iceland, Igbo, Ireland, Java, Kannada, Kazakh, Khmer, Kinyarwanda, Klingon, Kurd, Kyrgyz, Latinh, Latvia, Litva, Luxembourg, Lào, Macedonia, Malagasy, Malayalam, Malta, Maori, Marathi, Myanmar, Mã Lai, Mông Cổ, Na Uy, Nepal, Nga, Nhật, Odia (Oriya), Pashto, Pháp, Phát hiện ngôn ngữ, Phần Lan, Punjab, Quốc tế ngữ, Rumani, Samoa, Serbia, Sesotho, Shona, Sindhi, Sinhala, Slovak, Slovenia, Somali, Sunda, Swahili, Séc, Tajik, Tamil, Tatar, Telugu, Thái, Thổ Nhĩ Kỳ, Thụy Điển, Tiếng Indonesia, Tiếng Ý, Trung, Trung (Phồn thể), Turkmen, Tây Ban Nha, Ukraina, Urdu, Uyghur, Uzbek, Việt, Xứ Wales, Yiddish, Yoruba, Zulu, Đan Mạch, Đức, Ả Rập, dịch ngôn ngữ.

Copyright ©2025 I Love Translation. All reserved.

E-mail: