In order to activate UV Unit properly, UV Lamp requires determined time forwarming up. Namely, water can be injected into Ballast Tank, only after 5minutes for warming-up or only when UV Lamp reaches to normal status.During this process, Warming-up Pilot Lamp attached into Control Panel willkeep its On-status, and will be off after its activation. Warming-up Pilot Lamp’soff represents inflow of water which was treated appropriately. Therefore,Ballasting Valve must be opened, while Overboard valve shall be closed. Uponfinishing each valve’s activation, Warming Up lamp, which is flickering, will beoff.