• 1000Base-LX (1-Gigabit Ethernet)– IEEE 802.3z standard– 1000: 1000 M dịch - • 1000Base-LX (1-Gigabit Ethernet)– IEEE 802.3z standard– 1000: 1000 M Việt làm thế nào để nói

• 1000Base-LX (1-Gigabit Ethernet)–

• 1000Base-LX (1-Gigabit Ethernet)
– IEEE 802.3z standard
– 1000: 1000 Mbps throughput
– Base: baseband transmission
– LX: reliance on 1300 nanometers long wavelengths
– Longer reach than any other 1-gigabit technology
– Single-mode fiber: 5000 meters maximum segment
– Multimode fiber: 550 meters maximum segment
– One repeater between segments
– Excellent choice for long backbones
• Ethernet Standards for Fiber-Optic Cable (cont’d.)
• 1000Base-SX (1-Gigabit Ethernet)
– Differences from 1000Base-LX
• Multimode fiber-optic cable (installation less expensive)
• Uses short wavelengths (850 nanometers)
– Maximum segment length dependencies
• Fiber diameter, modal bandwidth used to transmit signals
– Best suited for shorter network runs than 1000Base-LX
• Ethernet Standards for Fiber-Optic Cable (cont’d.)
• 1000Base-SX (cont’d.)
– Modal bandwidth measurement
• Highest frequency of multimode fiber signal (over specific distance)
• MHz-km
• Higher modal bandwidth, multimode fiber caries signal reliably longer
– 50 micron fibers: 550 meter maximum length
– 62.5 micron fibers: 275 meter maximum length
– One repeater between segments

• 10-Gigabit Fiber-Optic Standards
• Extraordinary potential for fiber-optic cable
• 802.3ae standard
– Fiber-optic Ethernet networks
– Transmitting data at 10 Gbps
– Several variations
– Common characteristics
• Star topology, allow one repeater, full-duplex mode
– Differences between 10 gigabit standards:
• Signal’s light wavelength; maximum allowable segment length
• 10-Gigabit Fiber-Optic Standards (cont’d.)
• 10GBase-SR and 10GBase-SW
– 10G: 10 Gbps
– Base: baseband transmission
– S: short reach
– Physical layer encoding
• R works with LAN fiber connections
• W works with SONET fiber connections
– Multimode fiber: 850 nanometer signal transmission
– Maximum segment length
• Depends on fiber diameter
• 10-Gigabit Fiber-Optic Standards (cont’d.)
• 10GBase-LR and 10GBase-LW
– 10G: 10 Gbps
– Base: baseband transmission
– L: long reach
– Single-mode fiber: 1310 nanometer signal transmission
– Maximum segment length
• 10,000 meters
– 10GBase-LR & 10GBase-LW: suited for WAN or MAN
• W: encoding method for SONET WAN links
• 10-Gigabit Fiber-Optic Standards (cont’d.)
• 10GBase-ER and 10GBase-EW
– E: extended reach
– Single-mode fiber
• Transmit signals with 1550 nanometer wavelengths
– Longest fiber-optic segment reach
• 40,000 meters (25 miles)
– 10GBase-EW
• Encoding for SONET
– Best suited for WAN use
• IEEE has plans for 40 & 100 gigabit Ethernet
• Summary of Common Ethernet Standards
• Ethernet Frames
• Four types
– Ethernet_802.2 (Raw)
– Ethernet_802.3 (Novell proprietary)
– Ethernet_II (DIX)
– Ethernet_SNAP
• Frame types differ slightly
– Coding and decoding packets
• No relation to topology, cabling characteristics
• Framing
– Independent of higher-level layers
• Using and Configuring Frames
• Ensure all devices use same, correct frame type
– Node communication
• Ethernet_II (DIX) used today
• Frame type configuration
– Specified using NIC configuration software
– NIC autodetect or autosense
• Importance
– Know frame type for troubleshooting
• Frame Fields
• Common fields
– 7-byte preamble, 1-byte start-of-frame delimiter
– SFD (start-of-frame delimiter) identifies where data field begins
– 14-byte header
– 4-byte FCS (frame check sequence)
– Frame size range: 64 to 1518 total bytes
• Larger frame sizes result in faster throughput
– Improve network performance (sending more data at a time)
• Ethernet_II (DIX)
• Developed by DEC, Intel, Xerox (abbreviated DIX)
– Before IEEE
• Contains 2-byte type field
– Identifies the Network layer protocol
• Most commonly used on contemporary Ethernet networks
• PoE (Power over Ethernet)
• IEEE 802.3af standard
– Supplying electrical power over Ethernet connections
• Two device types
– PSE (power sourcing equipment)
– PDs (powered devices)
• Requires Cat 5 or better copper cable
• Connectivity devices must support PoE
• Compatible with current 802.3 installations
• PoE (cont’d.)
• Summary
• Physical topology describes basic network physical layout
– Examples: bus, ring, star, hybrid
• Logical topology describes signal transmission
• Network backbones
– Serial, distributed, collapsed, parallel
• Switching
– Manages packet filtering, forwarding
• Ethernet
– Cabling specifications, data frames, PoE
0/5000
Từ: -
Sang: -
Kết quả (Việt) 1: [Sao chép]
Sao chép!
• 1000Base-LX (1-Gigabit Ethernet)– IEEE 802.3z standard– 1000: 1000 Mbps throughput– Base: baseband transmission– LX: reliance on 1300 nanometers long wavelengths– Longer reach than any other 1-gigabit technology– Single-mode fiber: 5000 meters maximum segment– Multimode fiber: 550 meters maximum segment– One repeater between segments– Excellent choice for long backbones• Ethernet Standards for Fiber-Optic Cable (cont’d.)• 1000Base-SX (1-Gigabit Ethernet)– Differences from 1000Base-LX• Multimode fiber-optic cable (installation less expensive)• Uses short wavelengths (850 nanometers)– Maximum segment length dependencies• Fiber diameter, modal bandwidth used to transmit signals– Best suited for shorter network runs than 1000Base-LX• Ethernet Standards for Fiber-Optic Cable (cont’d.)• 1000Base-SX (cont’d.)– Modal bandwidth measurement• Highest frequency of multimode fiber signal (over specific distance)• MHz-km• Higher modal bandwidth, multimode fiber caries signal reliably longer– 50 micron fibers: 550 meter maximum length– 62.5 micron fibers: 275 meter maximum length– One repeater between segments• 10-Gigabit Fiber-Optic Standards• Extraordinary potential for fiber-optic cable• 802.3ae standard– Fiber-optic Ethernet networks– Transmitting data at 10 Gbps– Several variations– Common characteristics• Star topology, allow one repeater, full-duplex mode– Differences between 10 gigabit standards:• Signal’s light wavelength; maximum allowable segment length• 10-Gigabit Fiber-Optic Standards (cont’d.)• 10GBase-SR and 10GBase-SW– 10G: 10 Gbps– Base: baseband transmission– S: short reach– Physical layer encoding• R works with LAN fiber connections• W works with SONET fiber connections– Multimode fiber: 850 nanometer signal transmission– Maximum segment length • Depends on fiber diameter• 10-Gigabit Fiber-Optic Standards (cont’d.)• 10GBase-LR and 10GBase-LW– 10G: 10 Gbps– Base: baseband transmission– L: long reach– Single-mode fiber: 1310 nanometer signal transmission– Maximum segment length• 10,000 meters– 10GBase-LR & 10GBase-LW: suited for WAN or MAN • W: encoding method for SONET WAN links• 10-Gigabit Fiber-Optic Standards (cont’d.)• 10GBase-ER and 10GBase-EW– E: extended reach– Single-mode fiber• Transmit signals with 1550 nanometer wavelengths– Longest fiber-optic segment reach• 40,000 meters (25 miles)– 10GBase-EW• Encoding for SONET– Best suited for WAN use• IEEE has plans for 40 & 100 gigabit Ethernet• Summary of Common Ethernet Standards• Ethernet Frames• Four types– Ethernet_802.2 (Raw)– Ethernet_802.3 (Novell proprietary)– Ethernet_II (DIX)– Ethernet_SNAP• Frame types differ slightly– Coding and decoding packets• No relation to topology, cabling characteristics• Framing– Independent of higher-level layers• Using and Configuring Frames• Ensure all devices use same, correct frame type– Node communication• Ethernet_II (DIX) used today• Frame type configuration– Specified using NIC configuration software– NIC autodetect or autosense• Importance– Know frame type for troubleshooting• Frame Fields• Common fields– 7-byte preamble, 1-byte start-of-frame delimiter– SFD (start-of-frame delimiter) identifies where data field begins– 14-byte header– 4-byte FCS (frame check sequence)– Frame size range: 64 to 1518 total bytes• Larger frame sizes result in faster throughput– Improve network performance (sending more data at a time)• Ethernet_II (DIX)• Developed by DEC, Intel, Xerox (abbreviated DIX)– Before IEEE• Contains 2-byte type field– Identifies the Network layer protocol• Most commonly used on contemporary Ethernet networks• PoE (Power over Ethernet)• IEEE 802.3af standard– Supplying electrical power over Ethernet connections• Two device types– PSE (power sourcing equipment)– PDs (powered devices)• Requires Cat 5 or better copper cable• Connectivity devices must support PoE• Compatible with current 802.3 installations• PoE (cont’d.)• Summary• Physical topology describes basic network physical layout– Examples: bus, ring, star, hybrid• Logical topology describes signal transmission• Network backbones– Serial, distributed, collapsed, parallel• Switching– Manages packet filtering, forwarding• Ethernet– Cabling specifications, data frames, PoE
đang được dịch, vui lòng đợi..
Kết quả (Việt) 2:[Sao chép]
Sao chép!
• 1000Base-LX (1-Gigabit Ethernet)
- Tiêu chuẩn IEEE 802.3z
- 1000: 1000 Mbps
- Base: truyền baseband
- LX: sự phụ thuộc vào bước sóng dài 1300 nm
- Tầm xa hơn hẳn các công nghệ 1-gigabit khác
- cáp quang single-mode : 5000 mét segment tối đa
- Đa sợi: 550 mét tối đa phân khúc
- Một repeater giữa các phân đoạn
- lựa chọn tuyệt vời cho xương sống lâu
(. tt) • Ethernet tiêu chuẩn cho Fiber-Optic Cable
• 1000Base-SX (1-Gigabit Ethernet)
- Chênh từ 1000Base-LX
• Multimode cáp sợi quang (cài đặt ít tốn kém)
• Sử dụng các bước sóng ngắn (850 nanomet)
- tối đa phụ thuộc chiều dài phân đoạn
• Đường kính sợi, băng thông phương thức được sử dụng để truyền tín hiệu
- phù hợp nhất cho chạy mạng ngắn hơn 1000Base-LX
• Tiêu chuẩn Ethernet cho Fiber-Optic Cable (tt.)
• 1000Base-SX (tt.)
- Modal đo băng thông
• tần số cao nhất của tín hiệu cáp quang đa (trên khoảng cách cụ thể)
• MHz-km
• băng thông cao hơn phương thức, sợi đa sâu răng hiệu đáng tin cậy còn
- 50 sợi micron: chiều dài tối đa 550 mét
- 62,5 micron sợi: chiều dài tối đa 275 mét
- Một repeater giữa các phân đoạn • Tiêu chuẩn 10-Gigabit Fiber-Optic • Tiềm năng bất thường cho cáp sợi quang • Tiêu chuẩn 802.3ae - Fiber- mạng Ethernet quang - Truyền dữ liệu ở tốc độ 10 Gbps - Một số biến thể - đặc điểm chung • sao topology, cho phép một repeater, full-duplex mode - Sự khác nhau giữa 10 tiêu chuẩn gigabit: • bước sóng ánh sáng tín hiệu của; Chiều dài tối đa cho phép phân khúc • Tiêu chuẩn 10-Gigabit Fiber-Optic (tt.) • 10GBASE-SR và 10GBASE-SW - 10G: 10 Gbps - Base: baseband truyền - S: tầm ngắn - lớp vật lý mã hóa • R làm việc với mạng LAN kết nối sợi • W làm việc với các kết nối sợi SONET - Đa xơ: truyền tín hiệu 850 nanomet - chiều dài đoạn tối đa • Phụ thuộc vào đường kính sợi (. tt) • Tiêu chuẩn 10-Gigabit Fiber-Optic • 10GBASE-LR và 10GBASE-LW - 10G : 10 Gbps - Base: truyền baseband - L: khoảng cách xa - Single-mode: truyền tín hiệu 1310 nanomet - chiều dài đoạn tối đa • 10.000 mét - 10GBASE-LR & 10GBASE-LW: phù hợp cho WAN hoặc MAN • W: phương pháp mã hóa cho SONET liên kết WAN • Tiêu chuẩn 10-Gigabit Fiber-Optic (tt.) • 10GBASE-ER và 10GBASE-EW - E: mở rộng tầm - Single-mode • Tín hiệu Transmit với bước sóng 1550 nm - Longest quang phân khúc tầm • 40.000 mét (25 dặm) - 10GBASE-EW • Encoding cho SONET - phù hợp nhất cho WAN sử dụng • IEEE đã có kế hoạch cho 40 & 100 gigabit Ethernet • Tóm tắt các tiêu chuẩn Ethernet Common Frames • Ethernet • Bốn loại - Ethernet_802.2 (Raw) - Ethernet_802.3 (Novell độc quyền) - Ethernet_II (DIX) - Ethernet_SNAP • Các loại khung khác nhau đôi chút - Mã hóa và giải mã các gói tin • Không liên quan đến cấu trúc liên kết, đặc cáp • Framing - độc lập của các lớp cao hơn • Sử dụng và cấu hình Frames • Đảm bảo tất cả các thiết bị sử dụng cùng, đúng loại khung - Node truyền thông • Ethernet_II (DIX) được sử dụng ngày nay • Khung kiểu cấu hình - Specified sử dụng phần mềm cấu hình NIC - NIC autodetect hoặc tự cảm nhận • Tầm quan trọng - Biết loại khung cho xử lý sự cố • Fields Khung • Các trường chung - 7-byte mào đầu , 1-byte bắt đầu-của-frame delimiter - SFD (start-of-frame delimiter) xác định, nơi trường dữ liệu bắt đầu - 14-byte tiêu đề - 4-byte (frame check) FCS - Khung kích thước khoảng: 64-1518 tổng số byte • Kích thước khung hình lớn hơn dẫn đến thông lượng nhanh hơn - Cải thiện hiệu suất mạng (gửi nhiều dữ liệu tại một thời điểm) • Ethernet_II (DIX) • Phát triển bởi DEC, Intel, Xerox (viết tắt là DIX) - Trước khi IEEE • Chứa trường loại 2-byte - Xác định giao thức lớp mạng • Thông thường nhất được sử dụng trên các mạng Ethernet hiện đại • PoE (Power over Ethernet) • IEEE 802.3af chuẩn - Cung cấp năng lượng điện trên các kết nối Ethernet • Hai loại thiết bị - PSE (thiết bị điện nguồn) - PD (thiết bị hỗ trợ) • Yêu cầu Cát 5 hoặc tốt hơn đồng cáp • Kết nối thiết bị phải hỗ trợ PoE • Tương thích với 802,3 cài đặt hiện tại • PoE (tt.) • Tóm tắt • topology vật lý mô tả cơ bản mạng vật lý layout - Ví dụ: xe buýt, nhẫn, sao, lai • topo logic mô tả tín hiệu truyền xương sống • Mạng - Serial, phân phối, bị sụp đổ, song song • Switching - Quản lý lọc gói, chuyển tiếp • Ethernet - thông số kỹ thuật cáp, khung dữ liệu, PoE



































































































đang được dịch, vui lòng đợi..
 
Các ngôn ngữ khác
Hỗ trợ công cụ dịch thuật: Albania, Amharic, Anh, Armenia, Azerbaijan, Ba Lan, Ba Tư, Bantu, Basque, Belarus, Bengal, Bosnia, Bulgaria, Bồ Đào Nha, Catalan, Cebuano, Chichewa, Corsi, Creole (Haiti), Croatia, Do Thái, Estonia, Filipino, Frisia, Gael Scotland, Galicia, George, Gujarat, Hausa, Hawaii, Hindi, Hmong, Hungary, Hy Lạp, Hà Lan, Hà Lan (Nam Phi), Hàn, Iceland, Igbo, Ireland, Java, Kannada, Kazakh, Khmer, Kinyarwanda, Klingon, Kurd, Kyrgyz, Latinh, Latvia, Litva, Luxembourg, Lào, Macedonia, Malagasy, Malayalam, Malta, Maori, Marathi, Myanmar, Mã Lai, Mông Cổ, Na Uy, Nepal, Nga, Nhật, Odia (Oriya), Pashto, Pháp, Phát hiện ngôn ngữ, Phần Lan, Punjab, Quốc tế ngữ, Rumani, Samoa, Serbia, Sesotho, Shona, Sindhi, Sinhala, Slovak, Slovenia, Somali, Sunda, Swahili, Séc, Tajik, Tamil, Tatar, Telugu, Thái, Thổ Nhĩ Kỳ, Thụy Điển, Tiếng Indonesia, Tiếng Ý, Trung, Trung (Phồn thể), Turkmen, Tây Ban Nha, Ukraina, Urdu, Uyghur, Uzbek, Việt, Xứ Wales, Yiddish, Yoruba, Zulu, Đan Mạch, Đức, Ả Rập, dịch ngôn ngữ.

Copyright ©2024 I Love Translation. All reserved.

E-mail: