The configuration and size of the business center is dependent on market conditions and sizeof hotel. Provide a minimum of two guest work stations, three recommended.o 300 to 500 Guestrooms 3 work stationso over 500 Guestrooms 5 work stations Design business center to screen guests from corridor traffic. In convention hotels, locate the business center on the same level with major functions.3.9.2. ArchitecturalEntrance 16-gauge, one-piece, welded, hollow-metal frame. Stile and rail, glazed and tempered, door. RFID electronic lockset, following specification in Section 7.12.Carpentry and Millwork Coordinate architectural millwork, shelving and storage with systems furniture.Windows Commercial storefront.3.9.3. Mechanical (Plumbing and HVAC) See also Sections 7.4, 7.5, 7.6.HVAC Dedicated digital thermostat, integrated with BMS, to control heating, ventilating, and airconditioning.3.9.4. Electrical (Power and Lighting) See also Section 7.8.Power Locate power outlets to coordinate with furniture and equipment. Provide one (1) quadplex outlet at each work station. If POS is located in business center, provide one (1) quadplex power outlet connected toemergency backup power supply. Provide emergency backup power to a minimum of one light fixture above the POS area.Lighting Variety of architectural and decorative light fixtures. 50 FC [500 lux] minimum at 30” [760 mm] AFF. Fluorescent fixtures with state-of-the art 25W T-8 lamps, CR Index of 82, with a
temperature range of 2700º - 3000º Kelvin and “instant-on” type ballast.
If Business Center is not fully-staffed, provide lighting control through occupancy sensor to
partially shut off or dim lights when room is not occupied. Provide a 10-minute minimum
shut-off delay.