Set Current Time and Day Synchronizing the controller's clock with the dịch - Set Current Time and Day Synchronizing the controller's clock with the Việt làm thế nào để nói

Set Current Time and Day Synchroniz

Set Current Time and Day
Synchronizing the controller's clock with the current time and day is an important first step in the programming
procedure. The timed events for all watering programs (when the satellite is in the Satellite Mode) are based on
the settings you will make here.
Use the following procedure to set the current time and day:
1. Press as needed to select Time/Day indicator.
2. Press – The hour digit(s) will begin flashing.
3. Press or to increase or decrease hour digit(s).
(Observe for correct a.m./p.m. time.)
4. Press – Minute digits will begin flashing.
5. Press or to increase or decrease minute digits.
6. Press – Day abbreviation will begin flashing.
7. Press or to select current day in either week of 14-day cycle.
8. Press to store new information into controller memory.
Set Station Run Time
Note the following Station Run Time characteristics:
• Run time can be set from one minute to eight hours and 59 minutes in one-minute increments.
• Each station can have a different assigned run time within each of 16 programs.
1. Press to select the Programs indicator. The Run Time
indicator will light. The program and station number will be shown in the
left display, and the station run time will be shown in the right display.
2. Press or to select the desired program number (1–16).
Note: If the station run time has been adjusted to a value other than 100%
using the % Adjust feature, the right display will alternate between the
programmed run time and the adjusted run time. The % Adjust LED will
light momentarily when the adjusted run time is displayed.
Example Shown: Program 1, station 2, run time 1 hour and 23 minutes.
3. Press – The station number digits will begin flashing.
4. Press or to select the desired station number
Note: The controller will automatically determine the number of station
mSet Station Run Time
Note the following Station Run Time characteristics:
• Run time can be set from one minute to eight hours and 59 minutes in one-minute increments.
• Each station can have a different assigned run time within each of 16 programs.
1. Press to select the Programs indicator. The Run Time
indicator will light. The program and station number will be shown in the
left display, and the station run time will be shown in the right display.
2. Press or to select the desired program number (1–16).
Note: If the station run time has been adjusted to a value other than 100%
using the % Adjust feature, the right display will alternate between the
programmed run time and the adjusted run time. The % Adjust LED will
light momentarily when the adjusted run time is displayed.
Example Shown: Program 1, station 2, run time 1 hour and 23 minutes.
3. Press – The station number digits will begin flashing.
4. Press or to select the desired station number
Note: The controller will automatically determine the number of station
modules installed and limit the display accordingly.
5. Press to select the run time display. The hours digit will begin
flashing.
6. Press or to select the desired hours of run time (0–8).
Note: If station operation is not desired during a particular program,
enter 0:00 run time.
7. Press – The minutes digits will begin flashing.
8. Press or to select desired minutes of run time (0–59).
9. Press to enter the information.
10. Repeat steps 4–8 for each station as required.
11. Press – Repeat steps 2–11 for all programs
0/5000
Từ: -
Sang: -
Kết quả (Việt) 1: [Sao chép]
Sao chép!
Set Current Time and Day Synchronizing the controller's clock with the current time and day is an important first step in the programming procedure. The timed events for all watering programs (when the satellite is in the Satellite Mode) are based on the settings you will make here. Use the following procedure to set the current time and day: 1. Press as needed to select Time/Day indicator. 2. Press – The hour digit(s) will begin flashing. 3. Press or to increase or decrease hour digit(s). (Observe for correct a.m./p.m. time.) 4. Press – Minute digits will begin flashing. 5. Press or to increase or decrease minute digits. 6. Press – Day abbreviation will begin flashing. 7. Press or to select current day in either week of 14-day cycle. 8. Press to store new information into controller memory. Set Station Run Time Note the following Station Run Time characteristics: • Run time can be set from one minute to eight hours and 59 minutes in one-minute increments. • Each station can have a different assigned run time within each of 16 programs. 1. Press to select the Programs indicator. The Run Time indicator will light. The program and station number will be shown in the left display, and the station run time will be shown in the right display. 2. Press or to select the desired program number (1–16). Note: If the station run time has been adjusted to a value other than 100% using the % Adjust feature, the right display will alternate between the programmed run time and the adjusted run time. The % Adjust LED will light momentarily when the adjusted run time is displayed. Example Shown: Program 1, station 2, run time 1 hour and 23 minutes. 3. Press – The station number digits will begin flashing. 4. Press or to select the desired station number Note: The controller will automatically determine the number of station mSet Station Run Time Note the following Station Run Time characteristics: • Run time can be set from one minute to eight hours and 59 minutes in one-minute increments. • Each station can have a different assigned run time within each of 16 programs. 1. Press to select the Programs indicator. The Run Time indicator will light. The program and station number will be shown in the left display, and the station run time will be shown in the right display. 2. Press or to select the desired program number (1–16). Note: If the station run time has been adjusted to a value other than 100% using the % Adjust feature, the right display will alternate between the programmed run time and the adjusted run time. The % Adjust LED will light momentarily when the adjusted run time is displayed. Example Shown: Program 1, station 2, run time 1 hour and 23 minutes. 3. Press – The station number digits will begin flashing. 4. Press or to select the desired station number Note: The controller will automatically determine the number of station modules installed and limit the display accordingly. 5. Press to select the run time display. The hours digit will begin flashing. 6. Press or to select the desired hours of run time (0–8). Note: If station operation is not desired during a particular program, enter 0:00 run time. 7. Press – The minutes digits will begin flashing. 8. Press or to select desired minutes of run time (0–59). 9. Press to enter the information. 10. Repeat steps 4–8 for each station as required. 11. Press – Repeat steps 2–11 for all programs
đang được dịch, vui lòng đợi..
Kết quả (Việt) 2:[Sao chép]
Sao chép!
Đặt Thời gian hiện tại và ngày
Đồng bộ đồng hồ của bộ điều khiển với thời gian hiện tại và ngày là một bước quan trọng đầu tiên trong việc lập trình
thủ tục. Các sự kiện thời gian cho tất cả các chương trình tưới nước (khi vệ tinh đang ở trong chế độ vệ tinh) được dựa trên
. Các thiết lập, bạn sẽ thực hiện ở đây
Sử dụng lệnh sau để cài đặt thời gian hiện tại và trong ngày:
1. Bấm khi cần thiết để lựa chọn chỉ số Thời gian / ngày.
2. Báo Chí - chữ số giờ (s) sẽ bắt đầu nhấp nháy.
3. Bấm hoặc để tăng hoặc giảm giờ chữ số (s).
(Quan sát cho đúng thời gian sáng / chiều).
4. Báo chí - chữ số phút sẽ bắt đầu nhấp nháy.
5. Bấm hoặc để tăng hoặc giảm chữ số phút.
6. Báo chí - Ngày viết tắt sẽ bắt đầu nhấp nháy.
7. Nhấn hoặc để chọn ngày hiện tại hoặc là tuần 14 ngày chu kỳ.
8. Bấm để lưu trữ thông tin mới vào bộ nhớ điều khiển.
Thiết lập Trạm Run Time
Lưu ý các đặc điểm Trạm Run Thời gian sau đây:
. * Chạy thời gian có thể được thiết lập từ 07:59 giờ và 59 phút thi đấu trong từng bước một phút
• Mỗi trạm có thể có một khác nhau được phân công thời gian chạy trong mỗi 16 chương trình.
1. Bấm để chọn các chỉ số chương trình. Run Time
chỉ thị sẽ sáng. Các chương trình và trạm số sẽ được hiển thị trong
màn hình bên trái, và thời gian chạy trạm sẽ được hiển thị tại màn hình hiển thị đúng.
2. Nhấn hoặc để chọn số chương trình mong muốn (1-16).
Lưu ý: Nếu thời gian trạm chạy đã được điều chỉnh đến một giá trị khác hơn 100%
bằng cách sử dụng% Điều chỉnh tính năng, màn hình hiển thị bên phải sẽ luân phiên giữa
thời gian chạy chương trình và điều chỉnh thời gian chạy. Các% Điều chỉnh đèn LED sẽ
sáng trong giây lát khi thời gian chạy điều chỉnh được hiển thị.
Ví dụ Thể hiện: Chương trình 1, trạm 2, chạy thời gian 1 giờ và 23 phút.
3. Báo chí - Các chữ số trạm sẽ bắt đầu nhấp nháy.
4. Nhấn hoặc để chọn số kênh bạn muốn
Lưu ý: Các bộ điều khiển sẽ tự động xác định số lượng các trạm
mSet Trạm Run Time
Lưu ý các đặc điểm Trạm Run Thời gian sau đây:
• Run thời gian có thể được thiết lập từ 07:59 giờ và 59 phút trong một phút increments.
• mỗi trạm có thể có một thời gian chạy giao khác nhau trong mỗi 16 chương trình.
1. Bấm để chọn các chỉ số chương trình. Run Time
chỉ thị sẽ sáng. Các chương trình và trạm số sẽ được hiển thị trong
màn hình bên trái, và thời gian chạy trạm sẽ được hiển thị tại màn hình hiển thị đúng.
2. Nhấn hoặc để chọn số chương trình mong muốn (1-16).
Lưu ý: Nếu thời gian trạm chạy đã được điều chỉnh đến một giá trị khác hơn 100%
bằng cách sử dụng% Điều chỉnh tính năng, màn hình hiển thị bên phải sẽ luân phiên giữa
thời gian chạy chương trình và điều chỉnh thời gian chạy. Các% Điều chỉnh đèn LED sẽ
sáng trong giây lát khi thời gian chạy điều chỉnh được hiển thị.
Ví dụ Thể hiện: Chương trình 1, trạm 2, chạy thời gian 1 giờ và 23 phút.
3. Báo chí - Các chữ số trạm sẽ bắt đầu nhấp nháy.
4. Nhấn hoặc để chọn số kênh bạn muốn
Lưu ý: Các bộ điều khiển sẽ tự động xác định số lượng các trạm
module cài đặt và hạn chế hiển thị phù hợp.
5. Bấm để chọn hiển thị thời gian chạy. Các giờ chữ số sẽ bắt đầu
nhấp nháy.
6. Nhấn hoặc để chọn giờ mong muốn thời gian chạy (0-8).
Lưu ý: Nếu hoạt động của trạm không mong muốn trong một chương trình cụ thể,
nhập 00:00 thời gian chạy.
7. Báo chí - Biên chữ số sẽ bắt đầu nhấp nháy.
8. Nhấn hoặc để chọn phút mong muốn thời gian chạy (0-59).
9. Nhấn để nhập thông tin.
10. Lặp lại các bước 4-8 cho mỗi trạm theo yêu cầu.
11. Báo chí - Lặp lại các bước 2-11 cho tất cả các chương trình
đang được dịch, vui lòng đợi..
 
Các ngôn ngữ khác
Hỗ trợ công cụ dịch thuật: Albania, Amharic, Anh, Armenia, Azerbaijan, Ba Lan, Ba Tư, Bantu, Basque, Belarus, Bengal, Bosnia, Bulgaria, Bồ Đào Nha, Catalan, Cebuano, Chichewa, Corsi, Creole (Haiti), Croatia, Do Thái, Estonia, Filipino, Frisia, Gael Scotland, Galicia, George, Gujarat, Hausa, Hawaii, Hindi, Hmong, Hungary, Hy Lạp, Hà Lan, Hà Lan (Nam Phi), Hàn, Iceland, Igbo, Ireland, Java, Kannada, Kazakh, Khmer, Kinyarwanda, Klingon, Kurd, Kyrgyz, Latinh, Latvia, Litva, Luxembourg, Lào, Macedonia, Malagasy, Malayalam, Malta, Maori, Marathi, Myanmar, Mã Lai, Mông Cổ, Na Uy, Nepal, Nga, Nhật, Odia (Oriya), Pashto, Pháp, Phát hiện ngôn ngữ, Phần Lan, Punjab, Quốc tế ngữ, Rumani, Samoa, Serbia, Sesotho, Shona, Sindhi, Sinhala, Slovak, Slovenia, Somali, Sunda, Swahili, Séc, Tajik, Tamil, Tatar, Telugu, Thái, Thổ Nhĩ Kỳ, Thụy Điển, Tiếng Indonesia, Tiếng Ý, Trung, Trung (Phồn thể), Turkmen, Tây Ban Nha, Ukraina, Urdu, Uyghur, Uzbek, Việt, Xứ Wales, Yiddish, Yoruba, Zulu, Đan Mạch, Đức, Ả Rập, dịch ngôn ngữ.

Copyright ©2025 I Love Translation. All reserved.

E-mail: